油气管线热电偶套管断裂原因分析
引用本文:张亚明.油气管线热电偶套管断裂原因分析[J].中国材料科技与设备,2014(3):71-73.
作者姓名:张亚明
作者单位:中国科学院金属研究所,辽宁沈阳110016
摘    要:某炼油厂油气管线上的一个热电偶套管发生断裂,使用时间仅6个月。对断裂套管进行了断口形貌、材质成分、金相组织等分析。结果表明,套管断裂主要原因是管线中油气流的冲击和湍流作用,引起套管的共振.进而产生疲劳断裂。

关 键 词:油气管线  热电偶套管  0Cr18Ni9不锈铜  疲劳断裂

Failure Analysis on the Fracture of a Thermowell for the Oil and Gas Pipeline
ZHANG Ya-ming.Failure Analysis on the Fracture of a Thermowell for the Oil and Gas Pipeline[J].Chinese Materials Science Technology & Equipment,2014(3):71-73.
Authors:ZHANG Ya-ming
Affiliation:ZHANG Ya-ming (Institute of Metal Research, Chinese Academy of Sciences, Liaoning, Shenyang, 110016, China)
Abstract:A thermowell for the oil and gas pipeline fractured in an oil refinery after service for only six months. To figure out the fail reason, fracture morphology, material composition, microstructure analysis for the thermowell are performed. The results show that the main reason for the thermowell failure is the resonance of the therrnowell caused by the impact of hydrocarbon flow and turbulent flowon the pipe, resulting in fatigue fracture.
Keywords:Oil and gas pipeline  Thermowell  0Cr18Ni9stainless steel  Fatigue fracture