摘    要:为了解决Honeywell HPA200精密气压计出现的严重超标的测量异常现象,通过分析对比相关的因素,查找验证HPA200精密气压计受到400 MHz无线对讲机的电磁干扰,依此设计硬件LC带阻滤波器,来滤除400 MHz左右的确定性干扰信号.最终通过实际测试和验证,LC带阻滤波器可以增强HPA200精密气压计抗干扰能...

关 键 词:气压计  无线对讲机  测量误差

Abnormal measure analysis of the Honeywell HPA200 precision barometer
Zhang Dong.Abnormal measure analysis of the Honeywell HPA200 precision barometer[J].Foreign Electronic Measurement Technology,2011(9):54-55,59.
Authors:Zhang Dong
Affiliation:Zhang Dong(Collage of Physics and Electronic Information,Yan'an University,Yan'an 716000,China)
Abstract:In order to solve the transnormal error which measured by the Honeywell HPA200 precision barometer,factors that related to the phenomenon are compared.The EMI characters of the HPA200 barometer have been found that the basic factor is the 400 MHz wireless interphone.Then,the hardware of the LC band reject filter is designed to lower the measure error value by the HPA200 precision barometer.The measure error is obviously reduced by the HPA200 barometer with the LC band reject filter in practice,and the abili...