采用反渗透—混床系统进行锅炉补给水处理 |
| |
引用本文: | 杨文君,何新玲.采用反渗透—混床系统进行锅炉补给水处理[J].热力发电,2001,30(3):52-53. |
| |
作者姓名: | 杨文君 何新玲 |
| |
作者单位: | 沂源热电有限公司, |
| |
摘 要: | 介绍了反渗透-混床除盐系统处理锅炉补给水时的运行经验。经4年的实践表明:(1)采用机械搅拌澄清池和三级过滤的系统,可以达到反渗透组件对进水水质的要求;(2)反渗透组件的脱盐率每年的降低1%-2%,在设计中必须考虑;(3)一般情况下,反渗透装置的出水应经过除碳器再送入混床;(4)混床的出力必须有足够的余量,以免影响供水。
|
关 键 词: | 锅炉 补给水处理 除盐系统 反渗透-混床系统 |
文章编号: | 1002-3364(2001)03-0052-02 |
BOILER MAKE-UP WATER
TREATMENT USING REVERSE OSMOSIS-MIXED BED SYSTEM |
| |
Abstract: | Operational experience of boiler make-up water treatment by using reverse osmosis-mixed bed demin-eralizing system has been described. Practice during the period of four years shows: (1) Settled water pond and three-stage filtration system with mechanical agitation can meet the requitments of reverse-osmosis components to the inlet water quality; (2) It must be considered in the design that the demineralization efficiency of reverse-osmosis components will be decreased about 1%~2% in every year; (3) In normal case, the outlet water from reverse-osmosis equipment shall enter into mixed bed via a decarbonator; (4) The output capacity of the mixed bed must have a sufficient surplus, to avoid its influence on the water supply. |
| |