热电厂锅炉房负压源环境清扫系统设计
引用本文:雒新峰.热电厂锅炉房负压源环境清扫系统设计[J].热力发电,2004,33(7):76-77,83.
作者姓名:雒新峰
作者单位:西安航空技术高等专科学校,陕西,西安,710077
摘    要:通过对热电厂和集中供热锅炉房吸尘系统的分析,阐明了用离心风机作为负压源的环境吸尘系统的实用性和经济性,指出了设计方法和保证系统安全运行应采取的措施。

关 键 词:热电厂  锅炉房  离心风机  吸尘系统  负压源  环境清扫
文章编号:1002-3364(2004)07-0076-02

DESIGN OF ENVIRONMENT CLEANING SYSTEM BY USING NEGATIVE PRESSURE SOURCE IN BOILER HOUSE OF THERMAL POWER PLANT
LUO Xin feng.DESIGN OF ENVIRONMENT CLEANING SYSTEM BY USING NEGATIVE PRESSURE SOURCE IN BOILER HOUSE OF THERMAL POWER PLANT[J].Thermal Power Generation,2004,33(7):76-77,83.
Authors:LUO Xin feng
Affiliation:LUO Xin feng
Abstract:Through analsysis of dust absorbing systems in thermal power plants and boiler house for central heating, the applicability and economic behavior of environment cleaning system of using centrifugal ventilator as negative pressure source have been expounded, and the design method, as well as measures taken to ensure safe operation of the said system being also pointed out.