凝结水溶氧超标的原因分析
引用本文:高欣,丁劲松,乔振江.凝结水溶氧超标的原因分析[J].华北电力技术,2007(A02):155-156.
作者姓名:高欣  丁劲松  乔振江
作者单位:天津国华盘山发电有限责任公司,天津蓟县301900
摘    要:在凝汽式火力发电厂中,凝结器是汽轮发电机组重要的附属设备之一。汽轮发电机组凝结水溶氧超标,将腐蚀机组凝结水系统,腐蚀产物在汽水系统中迁移,进一步腐蚀机组热力设备,结垢、积盐。分析了溶氧超标的原因,并给出了相应的解决措施。

关 键 词:发电机组  凝结水  溶氧
文章编号:1003-9171(2007)增刊2-0155-02
收稿时间:2007-08-27

Cause Analysis on Over-standard Dissolved Oxygen in Condensed Water
Gao Xin, Ding Jin-Song, Qiao Zhen-jiang.Cause Analysis on Over-standard Dissolved Oxygen in Condensed Water[J].North China Electric Power,2007(A02):155-156.
Authors:Gao Xin  Ding Jin-Song  Qiao Zhen-jiang
Abstract:Condensate pump is an important accessory of steam turbine in condensing thermal power plant. ]But corrosion would occur in condensate system when the dissolved oxygen in condensed water was overstandard, which released corrosive products in the steam-water system and caused scaling and mineral deposition in condensed water. In this paper some causes of over-standard dissolved oxygen in condensed water was analyzed and countermeasures were presented.
Keywords:generation unit  condensed water  dissolved oxygen