首页 | 官方网站   微博 | 高级检索  
     

125 MW 机高压前轴封漏汽量的测量计算及中压缸效率核算
引用本文:王学栋,张虎.125 MW 机高压前轴封漏汽量的测量计算及中压缸效率核算[J].山东电力技术,1998(3):53-56.
作者姓名:王学栋  张虎
作者单位:山东电力科学研究院
摘    要:介绍了莱芜电厂2号机改造后高压前轴封漏汽量测量原理和方法,计算出高压前轴封漏汽量,并代入热力性能试验计算过程中,核算了除掉轴封漏汽量影响的中压缸效率。此计算方法和图表普遍适用于125MW机组高压前轴封漏汽量的计算。

关 键 词:125MW机组  轴封漏汽量  中压缸效率  热力试验

Measurement and Calculation of HP Front Labyrinth Leakage and IP Efficiency Accounts of 125MW Units
Wang Xuedong et.al.Measurement and Calculation of HP Front Labyrinth Leakage and IP Efficiency Accounts of 125MW Units[J].Shandong Electric Power,1998(3):53-56.
Authors:Wang Xuedong etal
Affiliation:Wang Xuedong et.al
Abstract:This paper presents the theory and method for measuring the HP front labyrinth leakage which is calculated based on the experimental data,and the efficiency of IP has been checked taking the HP front labyrinth leakage into consideration.This calculation method and the charts are suitable for the calculation of HP front labyrinth leakage of 125 MW units.
Keywords:MW Turbine Generator  Labyrinth Leakage  IP Efficiency  Performance Test  