首页 | 官方网站   微博 | 高级检索  
     

基于分区域广域继电保护系统的故障识别算法
引用本文:金恩淑,汪有成,陈喜峰.基于分区域广域继电保护系统的故障识别算法[J].电力系统保护与控制,2014,42(9):68-73.
作者姓名:金恩淑  汪有成  陈喜峰
作者单位:东北电力大学电气工程学院,吉林 吉林 132012;东北电力大学电气工程学院,吉林 吉林 132012;河南省电力公司许昌供电公司,河南 许昌 461000
摘    要:随着电网的日趋扩大化与复杂化,基于广域多点信息的广域继电保护系统在向工程实际化转变的过程中越来越受到通信水平的制约。基于广域继电保护系统有限性的思想,对复杂结构的电网进行有序的区域划分,并将故障的识别与保护的动作在各个区域内完成,减小了对通信系统的压力。针对已划分的保护区域,提出了基于故障方向信息比较原理的区域故障识别算法,利用故障时方向元件判别的故障方向,经简单的运算,判断故障的位置。以IEEE10机39节点系统为例,对保护区域进行了划分,并对其中一个保护区域内的故障情况进行了仿真验证,其结果验证了故障识别算法的可行性。

关 键 词:广域继电保护  通信量  区域划分  故障识别
收稿时间:8/5/2013 12:00:00 AM
修稿时间:2013/9/18 0:00:00

Fault identification algorithm based on zone-division wide area protection system
JIN En-shu,WANG You-cheng and CHEN Xi-feng.Fault identification algorithm based on zone-division wide area protection system[J].Power System Protection and Control,2014,42(9):68-73.
Authors:JIN En-shu  WANG You-cheng and CHEN Xi-feng
Affiliation:School of Electrical Engineering, Northeast Dianli University, Jilin 132012, China;School of Electrical Engineering, Northeast Dianli University, Jilin 132012, China;Xuchang Power Supply Company, Henan Electric Power Company, Xuchang 461000, China
Abstract:As the grid becomes more magnified and complicated, wide area relaying protection system based on wide area multi-point information is bound increasingly by the communication level in the process of conversion to engineering practice. Based on the thinking of limitedness of wide area relaying protection system, the grid with complex structure is divided orderly, and fault identification and protection action are executed in each region, reducing the pressure of the communication system. By protected area, a regional fault identification algorithm based on fault direction information comparison is proposed. When a fault occured, it can make use of the fault direction information to judge fault position. Protected area is divided in IEEE10-machine 39-bus system, and taking one fault protected area as the example for simulation, the results show the feasibility of the fault identification algorithm.
Keywords:wide area relaying protection  communication volume  region division  fault identification
本文献已被 CNKI 等数据库收录!
点击此处可从《电力系统保护与控制》浏览原始摘要信息