首页 | 官方网站   微博 | 高级检索  
     

降低锅炉排烟温度的2种方式比较
引用本文:李建锋,朱超,冷杰,张全胜,尧国富.降低锅炉排烟温度的2种方式比较[J].中国电力,2012,45(7):28-33.
作者姓名:李建锋  朱超  冷杰  张全胜  尧国富
作者单位:1. 中国电力企业联合会科技开发服务中心,北京,100055
2. 国核工程有限公司,上海,200233
3. 东北电力科学研究院有限公司,辽宁沈阳,110006
摘    要:锅炉的排烟热损失是其各项热损失中最大的一项,因此,有必要采取一定的技术措施降低锅炉的排烟温度.为了给火电厂降低锅炉排烟温度提供技术参考,根据某135 MW循环流化床锅炉机组的实际特点,建立了不同降低排烟温度方法的计算模型,分析并比较了低压省煤器与前置式空气预热器等降低锅炉排烟温度技术方案的经济性.分析结果表明,采用水介质空气预热器,利用烟气余热加热锅炉送风是降低锅炉排烟温度综合效益最好的方式,采用该种方式投资回收期约为1.53年.由于能够控制进水温度,因此可以有效避免锅炉的低温腐蚀.

关 键 词:循环流化床锅炉  排烟热损失  余热利用  低压省煤器  空气预热器

Comparison of Two Methods for Reducing Boiler Exhaust Flue Gas Temperature
LI Jian-feng , ZHU Chao , LENG Jie , ZHANG Quan-sheng , YAO Guo-fu.Comparison of Two Methods for Reducing Boiler Exhaust Flue Gas Temperature[J].Electric Power,2012,45(7):28-33.
Authors:LI Jian-feng  ZHU Chao  LENG Jie  ZHANG Quan-sheng  YAO Guo-fu
Affiliation:1(1.Scientific and Technical Development ServiceCenter,China Electricity Council,Beijing 100055,China;2.State Nuclear Power Engineering Corp,Ltd.,Shanghai 200233,China;3.Northeast Electric Power Research Institute Co.,Ltd.,Shenyang 110006,China)
Abstract:Exhaust heat loss is the biggest heat loss of the boiler,it is necessary to take certain measures to reduce flue gas temperature of boiler.In order to provide technical references for reducing the flue gas temperature,according to the actual characteristics of a 135 MW circulating fluidized bed boiler unit,the several calculation models of reducing flue gas temperature were established,the economy of low pressure economizer and front-located air pre-heater for reducing the flue gas temperature were analyzed and compared.The analysis results show that using water-medium front-located air pre-heater to heating air supply for boiler by waste heat of flue gas is the best way for reducing flue gas temperature comprehensively and the pay back period of the way approximately was 1.53 years.It could avoid the low-temperature corrosion of the boiler because of the ability to con-trol the temperature of inlet water.
Keywords:circulating fluidized bed boiler  exhaust heat loss  waste heat utilization  low pressure economizer  air pre-heater
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号