首页 | 官方网站   微博 | 高级检索  
     

三维阶梯结构微混合器设计、制作及性能分析
引用本文:张贺,刘晓为,唐佳禄,韩小为,田丽.三维阶梯结构微混合器设计、制作及性能分析[J].哈尔滨工业大学学报,2016,48(4):54-59.
作者姓名:张贺  刘晓为  唐佳禄  韩小为  田丽
作者单位:微系统与微结构制造教育部重点实验室哈尔滨工业大学, 150001 哈尔滨,微系统与微结构制造教育部重点实验室哈尔滨工业大学, 150001 哈尔滨,黑龙江工程学院 电气与信息工程学院,150001 哈尔滨,微系统与微结构制造教育部重点实验室哈尔滨工业大学, 150001 哈尔滨,微系统与微结构制造教育部重点实验室哈尔滨工业大学, 150001 哈尔滨
基金项目:国家自然科学基金(61404036).
摘    要:为改善微纳尺度下流体的混合效果,在聚甲基丙烯酸甲酯(PMMA)基底材料上,设计制造了一款新型三维阶梯结构微混合器.混合器由一个T-型进样沟道和6个三维阶梯混合单元组成,采用超精密雕刻机在PMMA基片制作微米级结构,利用有机溶剂混溶浸泡法,在低温常压条件下键合得到.数值仿真结果表明:混合器效率受到台阶结构尺寸和流体速度的影响,当0.1≤Re≤5时,混合腔横截面的浓度方差σ0.1,接近充分混合;当流速在1~20 m L/h范围内时,将混合器用于微量溶液p H的调节取得了理想的结果.

关 键 词:微混合器  三维阶梯结构  混合效率  PMMA芯片制备  pH调节
收稿时间:2014/11/17 0:00:00

Design,manufacture and investigation of 3D step structures mixer
ZHANG He,LIU Xiaowei,TANG Jialu,HAN Xiaowei and TIAN Li.Design,manufacture and investigation of 3D step structures mixer[J].Journal of Harbin Institute of Technology,2016,48(4):54-59.
Authors:ZHANG He  LIU Xiaowei  TANG Jialu  HAN Xiaowei and TIAN Li
Affiliation:Key Laboratory of Micro-systems and Micro-structures ManufacturingHarbin Institute of Technology, Ministry of Education,150001 Harbin, China,Key Laboratory of Micro-systems and Micro-structures ManufacturingHarbin Institute of Technology, Ministry of Education,150001 Harbin, China,College of Electrical and Information Engineering, Heilongjiang Institute of Technology, 150001 Harbin, China,Key Laboratory of Micro-systems and Micro-structures ManufacturingHarbin Institute of Technology, Ministry of Education,150001 Harbin, China and Key Laboratory of Micro-systems and Micro-structures ManufacturingHarbin Institute of Technology, Ministry of Education,150001 Harbin, China
Abstract:To improve the fluid mixing effect under micro-nano scale condition, we designed and manufactured a novel micro mixer with three-dimensional step structure based on the polymethyl methacrylate (PMMA) substrate material. The mixer was composed by one T-shaped inlet channel and six three dimensional step mixing units. The mixer was fabricated by using ultra-precision engraving machine and bonded by miscible organic solvents bonding method at the atmospheric pressure and low temperature conditions. Then, a series of numerical simulations were executed to optimize the step structures and investigate the mixing efficiency. The results showed that, when the Reynolds number was between 0.1 and 5, the concentration variance of mixing chamber cross section was less than 0.1. The reagent was close to the uniform mixture. When the flow rate within 1~20 mL/h, the mixer can achieve on precise regulation of solution pH. The micro machining technology and miscible organic solvents bonding method which were used for fabricate the 3D step micromixer are convenient and cost-effective. The mixer was conducive to the further promotion and application of microfluidic chips.
Keywords:micromixer  three-dimensional step structure  mixing efficiency  PMMA chip preparation  pH adjustment
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《哈尔滨工业大学学报》浏览原始摘要信息
点击此处可从《哈尔滨工业大学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23