Application of improved high-performance evaporator
Authors:M Takada  JC Drake
Affiliation:1. Sasakura Engineering Co., Ltd., Osaka, Japan;2. Sasakura Engineering Co., (European Office), Horsham, England
Abstract:An improved horizontal-tube, thin-film evaporator that has a high heat transfer coefficient when working at low temperature is described. Applying this evaporator, it is possible to design a multi-effect distiller with a very large number of effects and a vapour compression distiller with an extemely small compression ratio, thus achieving a considerble reduction in energy consumption in those processes.Actual applications of this improved evaporator are described as used in a conventional multi-effect distiller, a solar heated multi-effect distiller, a double-effect reheat type distiller and a mechanical vapour compression distiller. A notable point of this paper is the introduction of a new vapour compression distiller that has a lower energy consumption than ever seawater reverse osmosis desalination plant.