Optimal size,hydraulic retention time and volatile solids loading rate of biogas unit using water hyacinth
Authors:S Vaidyanathan  K M Kavadia  L P Borkar  S P Mahajan
Abstract:With a view to evaluate the effects of hydraulic retention time and volatile solids loading rate on methane production using water hyacinth, experiments were conducted in a 160 dm3 capacity, well-mixed continuous digestion unit at ambient temperature. The optimal design of biogas plant using water hyacinth was elucidated, to provide a unit giving a maximum methane yield of 0.16 nm3 kg?1 volatile solids added, which was 60% greater than the conventional plant using cowdung. The calculations of optimal design factors were based on reactor size, hydraulic retention time and volatile solids loading rate; considerations were made of capital cost, running costs and operational revenue.
Keywords:Biogas plant  optimisation  hydraulic retention time  volatile solids loading  water hyacinth