摘    要:针对无法完全发挥效能的某厂二手空压机设备 ,结合厂方提出的改造目标 ,提出可在现有总体结构布置的情况下 ,采用通流能力好的三元叶轮、增加流道宽度等措施进行结构改造。经编制热力设计程序进行分析计算 ,结果表明这一方案切实可行

关 键 词:空气压缩机  热力设计  计算程序  改造分析
文章编号:0254-6094(2003)06-0335-05

Retrofit Design of Air Compressors Based on the Existing Structure
WU Long,CHEN Hualing.Retrofit Design of Air Compressors Based on the Existing Structure[J].Chemical Engineering & Machinery,2003,30(6):335-339.
Authors:WU Long  CHEN Hualing
Abstract:A structure retrofit was made of the used air compressors that could not well realize their efficiency by using three dimensional impellers with good flowability and extending the flow path width based on the retrofit aim of the factory and the total existing structure arrangement.The plan was feasible through analyzes and calculations of compiling thermodynamic design program.
Keywords:Air Compressor  Thermodynamic Design  Calculation Program  Retrofit Analysis