Abstract: | This work provides accurate solutions of the cylinder flux function I(0,1;T), first solved by Jaeger and Clarke, which can serve as reference values for electrochemical amperometric diffusion limited currents at a cylinder, as well as heat fluxes under equivalent conditions (fixed temperature at the cylinder surface). For the capped cylinder of varying lengths, reference values of time-dependent electrochemical currents are provided. Steady state currents at capped cylinders are presented and a function is provided that fits the simulated values to within 1%. All of these are more accurate than in previous works. |
| |