首页 | 官方网站   微博 | 高级检索  
     

高坝联合泄洪消力塘底板上举力分布特性研究
引用本文:王怀明,杨敏.高坝联合泄洪消力塘底板上举力分布特性研究[J].长江科学院院报,2012,29(7):53-56.
作者姓名:王怀明  杨敏
作者单位:天津大学 水利工程仿真与安全国家重点实验室,天津300072
基金项目:国家自然科学基金面上项目资助
摘    要:为研究多孔联合泄洪对上举力分布的影响,通过某工程1∶50模型试验对坝后水垫塘底板块上举力大小及分布特性进行了测试,并对多孔联合泄洪和表、深孔单独泄洪时的最大上举力大小和分布进行了比较。经比较分析得出:表深孔联合泄洪情况下表深孔水舌冲击点附近的上举力,与表孔或深孔单独泄洪下相应位置的上举力相比,要明显减小;最大上举力的位置也有所改变,表孔冲击点附近后移,深孔冲击点附近前移。结果表明:表深孔水舌入水后形成大的旋滚相互影响,得不到充分发展,对底板的卷吸作用明显减弱,进而导致相应上举力值明显减小,最大上举力的位置也有所改变。

关 键 词:水利水电工程  上举力  联合泄洪  水工模型  高拱坝

Uplift Force Distribution on Plunge Pool Slab: Coalition Discharge from Surface and Bottom Outlets of High Dam
WANG Huai-ming , YANG Min.Uplift Force Distribution on Plunge Pool Slab: Coalition Discharge from Surface and Bottom Outlets of High Dam[J].Journal of Yangtze River Scientific Research Institute,2012,29(7):53-56.
Authors:WANG Huai-ming  YANG Min
Affiliation:State Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin300072, China
Abstract:To investigate the effect of discharge through surface outlets and bottom outlets simultaneously,we analyze the uplift force and its distribution on plunge pool slab through a 1∶50 model test.Large water rolls formed by the nappes from surface outlets and bottom outlets interact with each other,and thereby weakening the entrainment effect on the slab.As a result,the uplift force near the impact point of water nappe by coalition discharge from surface outlets and bottom outlets is obviously smaller than that by separate discharge from surface outlets or bottom outlets alone.In the case of coalition discharge,the location of maximum uplift force also changes,moving forward near bottom outlets and moving backward near surface outlets.
Keywords:water conservancy and hydropower engineering  uplift force  coalition discharge  hydraulic model  high arch dam
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《长江科学院院报》浏览原始摘要信息
点击此处可从《长江科学院院报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号