首页 | 官方网站   微博 | 高级检索  
     

不同升温速率下模块装药的烤燃特性分析
引用本文:刘静,赵非玉.不同升温速率下模块装药的烤燃特性分析[J].装备环境工程,2022,19(3):11-16.
作者姓名:刘静  赵非玉
作者单位:中国电子科技集团公司光电研究院,天津 300308
摘    要:目的 研究不同升温速率下模块装药烤燃特性的变化.方法 基于模块装药结构及其烤燃化学反应机理,提出基本假设,建立二维非稳态烤燃计算模型,通过数值模拟计算分析研究模块装药在不同工况下的烤燃特性.结果 在3.30、5.25、7.20 K/h的加热条件下,模块装药发生烤燃响应的着火温度分别为476.6、473.1、477.1 ...

关 键 词:模块装药  着火温度  烤燃特性  数值模拟  升温速率  温度云图
收稿时间:2021/12/23 0:00:00
修稿时间:2022/3/4 0:00:00

Analysis of Cook-Off Characteristics of Modular Charges at Different Heating Rates
LIU Jing,ZHAO Fei-yu.Analysis of Cook-Off Characteristics of Modular Charges at Different Heating Rates[J].Equipment Environmental Engineering,2022,19(3):11-16.
Authors:LIU Jing  ZHAO Fei-yu
Affiliation:Academy of Opto-Electronic, China Electronics Technology Group Corporation AOE CETC, Tianjin 300308, China
Abstract:This paper is to study the change of cook-off characteristics of modular charges at different heating rates. Based on the structure of the modular charge and its chemical reaction mechanism, the basic assumptions are put forward, a two-dimensional unsteady cook-off calculation model is established, and the cook-off characteristics of the modular charge under different working conditions are analyzed and studied through numerical simulation. Under the heating rates of 3.30, 5.25, and 7.20 K/h, the ignition temperatures at which the cook-off response of modular charge occurred are 476.6, 473.1 and 477.1 K. When the heating rate is not higher than 5.25 K/h, only one cook-off annular response region located at the single base charge in the radial center section of the module charge is produced; When the heating rate is higher than 5.25 K/h, the center point of the cook-off annular response region changes from a cook-off annular response region located in the radial center section of the module charge to two cook-off annular response regions symmetrical about the radial center section of the module charge. With the increase of heating rate, the center point of the annular response region of the cook-off moves outward from the center to the inner wall region and end face of the modular charge, the response time of cook-off has an exponential relationship with the heating rate, but the change of heating rate has little effect on the response temperature of cook-off.
Keywords:modular charge  ignition temperature  cook-off characteristics  numerical simulation  heating rate  temperature cloud pictures
本文献已被 万方数据 等数据库收录!
点击此处可从《装备环境工程》浏览原始摘要信息
点击此处可从《装备环境工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号