首页 | 官方网站   微博 | 高级检索  
     


The influence of recycle on a parallel-plate heat exchanger with insulation sheet inserted for double-pass operations
Affiliation:1. School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin 300401, China;2. Department of Civil Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;1. Laboratory of Heat and Mass Transfer (LTCM), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IGM-LTCM, Station 9, Lausanne CH-1015, Switzerland;2. Swiss Federal Laboratories for Materials Science and Technology (Empa), Feuerwerkerstrasse 39, Thun, CH-3602 Bern, Switzerland
Abstract:The influence of recycle on a parallel-plate heat exchanger of inserting in parallel an insulation sheet to divide an open duct into two channels for double-pass operations with uniform wall temperature has been studied analytically. The results are represented graphically and compared with those in an open duct (without an inserted insulation sheet) and a double-pass without recycle. Substantial improvement in heat transfer is obtainable by employing such a double-pass device with external refluxes, instead of using an open conduit with single-pass operations and using double-pass operations without recycle. The effect of insulation-sheet location on the enhancement of heat transfer efficiency as well as on the increment of power consumption, has been also discussed.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23