摘    要:结合实际,针对《高规》,探讨了民用建筑消防给水设计中室外消火栓数量的确定,水泵接合器数量的确定,消防水池客积的确定及消防给水系统的形式,以在保证安全的同时,达到经济合理,尽量节省投资。

关 键 词:高层建筑  消防设计  防火安全
收稿时间:2005-09-18

Discuss on several problems encountered in fire control water supply system design of tall buildings
GU Qiang,GA Xin.Discuss on several problems encountered in fire control water supply system design of tall buildings[J].Shanxi Architecture,2006,32(5):170-171.
Authors:GU Qiang  GA Xin
Affiliation:GU0 Qiang,GA0 Xin
Abstract:Combined with practical work, according to the code for fire protection design of tall buildings the problems encountered in fire control water supply system design of civil buildings such as the determination of numbers of fire hydrants, capacity of fire tank and form of water supply system are introduced in order to reduce investment and ensure the safety and rationality of design.