首页 | 官方网站   微博 | 高级检索  
     

基于Ventsim的深井线性热源对有效通风量的影响分析
引用本文:王从陆,李童.基于Ventsim的深井线性热源对有效通风量的影响分析[J].黄金科学技术,2019,27(2):271-277.
作者姓名:王从陆  李童
作者单位:中南大学资源与安全工程学院,湖南 长沙,410083;中南大学资源与安全工程学院,湖南 长沙,410083
基金项目:国家自然科学基金项目“微米级尘雾耦合作用力机理及其效能优化研究”(编号:51674289)和国家重点研发计划项目“金属非金属矿山采运过程物化防尘技术与装备”(编号:2017YFC0805204)
摘    要:随着矿产资源开采深度的日益增加,深井通风因其通风网络规模大、环境复杂等,面临着成本及能耗高的问题。考虑到深井高温环境具有大量且便利的热能,基于对深井温差能可利用性的理论分析,通过在回风井深部设置线性热源,运用Ventsim数值模拟的方法,研究了线性热源作用下温差能对矿井有效通风量的影响。结果表明:在矿井巷道干球温度处于25~48 的范围内,线性热源的温度提升与矿井有效风量的提高呈正相关,且回风井内二者呈近似线性相关,但对于矿井底部风量基础值较小的水平巷道,回风井内线性热源对其有效风量的提升不明显;在线性热源作用下,不同的温度递增设置方案对于有效风量的提升也有一定影响,在线性热源温差范围相同的情况下,对温差间隔进行小幅度、多区间的合理设置,有利于提高温差能的利用率。

关 键 词:线性热源  深井高温  有效风量  通风优化  Ventsim  数值模拟  温差能
收稿时间:2018-05-25
修稿时间:2018-08-29

Analysis of Influence of Deep Mine’s Linear Heat Source on Effective Ventilation Based on Ventsim Software
Conglu WANG,Tong LI.Analysis of Influence of Deep Mine’s Linear Heat Source on Effective Ventilation Based on Ventsim Software[J].Gold Science and Technololgy,2019,27(2):271-277.
Authors:Conglu WANG  Tong LI
Affiliation:School of Resources and Safety Engineering, Central South University, Changsha 410083, Hunan,China
Abstract:The huge energy consumption is the main problem in the mining of mineral resources in China.In recent years,due to the continuous consumption of underground mineral resources,deep mining operations are becoming more and more common.Increasing the effective ventilation of mines is critical to saving energy consumption.The high-temperature environment of deep mines stores a large amount of heat energy,and if it can be comprehensively utilized,it will produce huge benefits.In recent years,domestic and foreign researches on the absorption,storage,and transformation of thermal energy have yielded rich results.Based on this,the temperature difference formed between the high temperature of the deep well and the surface temperature can be used as an energy source,and the temperature difference can be used as a ventilation power can improve the effective ventilation of deep mines.This paper starts with the theoretical analysis, and analyzes the state change of ideal gas in thermal environment.Then the feasibility of temperature difference energy for improving air volume is demonstrated.Secondly, a deep mine model was established based on Ventsim three-dimensional ventilation software, and the heat energy stored in deep mines was simulated by setting a linear heat source. Finally,the representative necessary ventilation roadway in mine structure, such as main air inlet shaft, main return shaft and horizontal tunneling roadway, is selected as the research object to analyze the influence of different temperature setting and layout of linear heat source on the effective ventilation volume of mine.The specific scheme is as follows:The linear heat source power was increased from 1 000 W/m to 3 500 W/m incremented by 500 W/m, so as to study the change of effective mine ventilation under the action of linear heat source at different temperatures.The linear heat source was set to a range of 1 000 W/m to 4 000 W/m, and the linear heat source was successively distributed according to the increasing of 1 000 W/m and 500 W/m in the same section of return air shaft, to observe the influence of the linear heat source with different power decreasing gradient distribution on the effective ventilation volume of the mine. The results of the study are as follows: In mine laneway when the dry bulb temperature at 35~48 ℃, the temperature rise of the linear heat source is linear positively correlated with the increase of the effective mine air volume. For the horizontal roadway with a small air volume basis value at the bottom of the mine, the linear heat source in the return air shaft does not significantly improve its effective air volume.When the temperature difference range of the linear heat source is the same, the reasonable setting of small amplitude and multiple intervals of the temperature difference can generate effective pressure drop, improve the dynamic effect of the temperature difference energy, and thus improve the effective ventilation volume. And the scheme is more economical and can improve the utilization rate of temperature difference energy.
Keywords:linear heat source  high temperature of deep well  effective ventilation  ventilation optimization  Ventsim  numerical simulation  temperature difference energy  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《黄金科学技术》浏览原始摘要信息
点击此处可从《黄金科学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23