首页 | 官方网站   微博 | 高级检索  
     

对比增强磁共振冠状动脉成像的初步研究
引用本文:张兆琪,马晓海,晏子旭,赵轶柯,范占明,吕飙,贺毅.对比增强磁共振冠状动脉成像的初步研究[J].中国医学影像技术,2003,19(10):1306-1309.
作者姓名:张兆琪  马晓海  晏子旭  赵轶柯  范占明  吕飙  贺毅
作者单位:首都医科大学附属北京安贞医院医学影像科,北京,100029
摘    要:目的 利用三维对比增强磁共振血管成像技术 ,对正常冠状动脉成像进行初步研究。方法  30例健康志愿者进行对比增强磁共振冠状动脉成像 ,采用 3DFLASH压脂序列 ,心电触发、屏气状态下分别行左、右冠状动脉成像 ;经后处理得到左主干、左前降支、左回旋支和右冠脉的图像 ,对图像质量进行评分 ,并且测量血管分支显示长度。结果 对其中 2 6例健康志愿者的 10 4支冠状动脉分支进行了分析 ,85支血管较满意显示 (评分在 3分以上 ) ,其中左前降支 2 6例和右冠脉 2 6例均满意显示 ,左主干和左回旋支显示满意者分别为 2 1例和 12例。血管显示长度 :左主干(1.5 4± 0 .31)cm、左前降支 (6 .6 4± 0 .5 4 )cm、左回旋支 (2 .4 6± 0 .98)cm、右冠脉 (9.75± 1.14 )cm。显示血管分支长度与国内外同类研究相比近似。结论 对比增强磁共振技术可用于冠状动脉成像 ,但存在一些技术障碍。

关 键 词:磁共振血管造影术  磁共振成像  冠状动脉
文章编号:1003-3289(2003)10-1306-04
收稿时间:2003/6/11 0:00:00
修稿时间:2003年6月11日

Contrast-Enhanced Magnetic Resonance of Coronary Angiography: Initial Experiences
ZHANG Zhao-qi,MA Xiao-hai,YAN Zi-xu,ZHAO Yi-ke,FAN Zhan-ming,LV Biao and HE Yi.Contrast-Enhanced Magnetic Resonance of Coronary Angiography: Initial Experiences[J].Chinese Journal of Medical Imaging Technology,2003,19(10):1306-1309.
Authors:ZHANG Zhao-qi  MA Xiao-hai  YAN Zi-xu  ZHAO Yi-ke  FAN Zhan-ming  LV Biao and HE Yi
Affiliation:Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China;Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China;Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China;Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China;Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China;Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China;Department of Radiology, Anzhen Hospital, Capital University of Medical Sciences, Beijing 100029, China
Abstract:Objective To initial study the technology of the native coronary artery image by using three-dimensional contrast-enhanced MR angiography. Methods Thirty healthy volunteers underwent imaging in left and right coronary artery with 3D FLASH sequence, combined with fat suppression, electrocardiogram triggered and breath-hold. After post-processing, coronary arteries images were acquired, including left main stem (LM), left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA). A grading system was used to evaluate the image quality. Furthermore, lengths of branches vessel were measured. Results Twenty-six volunteers with 104 branches vessel were analyzed. And 85 branches of them were graded more than 3. The LAD branch and RCA branch of 26 volunteers could be seen, at the same time, only LM branch of 21 and LCX branch of 12 volunteers was seen. Moreover, the average lengths of four branches were (1.54±0.31)cm, (6.64±0.54)cm, (2.46±0.98)cm and (9.75±1.14)cm, respectively. This results were close to same studies in internal or abroad. Conclusion Contrast-enhanced MRA can image the coronary artery, yet some questions need solve.
Keywords:Magnetic resonance angiography  Magnetic resonance imaging  Coronary artery
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号