Abstract:The paper compares the energy requirements of single and dual purpose MSF distillation with seawater reverse osmosis plant. Energy consumptions are given both as heat and power consumptions for distillation and as power consumption for R.O. To enable a true comparison to be made these inputs are referred back to the heat inputs from fuel needed at the boiler plant or appropriate thermal power plant.Energy recovery is also considered for reverse osmosis and it is shown that the energy input can be expected to decrease by some 35% for a typical example.Although the prime energy input needed for reverse osmosis is shown to be substantially lower than for dual purpose distillation, the overall costs taking account Of capital charges, energy, replacements and other operating costs, are found to be in a band width of about 5% for plants in the range of 5000 to 15000 m3/day. Reverse osmosis plant water costs are significantly less than distillation if membrane life increases from 3 years to 5 years, particularly with small plant capacities.