首页 | 官方网站   微博 | 高级检索  
     

CO压缩机优化运行总结
作者姓名:梁慧  汪亮宇
作者单位:兖矿鲁南化工有限公司
摘    要:为确保原CO压缩机在净化系统升级改造项目实施后能安全稳定运行,采取了流程优化、工艺条件论证、设备缺陷排查、联锁指标重新确定等一系列措施。改造措施实施后,CO压缩机出口压力稳定在3.23 MPa左右,有效缓解了前后工序压力波动对压缩机稳定运行的影响,各级水冷却器的换热效果也得到了较大的改善。

关 键 词:CO压缩机  流程优化  运行总结

Sum-Up of CO Compressor Optimized Operation
Authors:LIANG Hui  WANG Liangyu
Affiliation:(Yankuang Lunan Chemical Co.,Ltd.,Tengzhou,Shandong 277527,China)
Abstract:In order to ensure the safe and stable operation of the original CO compressor after implementation of the purification system upgrade project,a series of measures such as process optimization,process condition demonstration,equipment defect inspection,and re-determination of interlocking indicators are taken.After the implementation of the reform measures,the CO compressor outlet pressure is stabilized at about 3.23 MPa,which effectively alleviates the impact of the pressure fluctuations of the front and back processes on the stable operation of the compressor,and the heat exchange effect of the water coolers at all stages is also greatly improved.
Keywords:CO compressor  process optimization  operation summary