摘    要:针对并联逆变电源设计的难点--启动问题,提出了一种扫频式它激到自激转换的启动电路,电路由鉴相部分和启动部分构成.文中详细分析了启动过程的相关问题,给出了仿真结果,并研制了一台50 kW样机.实验结果证明,该启动电路从18 kHz到38 kHz,均能实现扫频的成功启动,扫频范围高达20 kHz,扫频范围宽,启动成功率可达95%以上.

关 键 词:并联逆变  扫频式启动  感应加热
文章编号:1001-6988(2007)01-0034-03
修稿时间:2006年9月4日

Swept-Frequency Start Circuit for Parallel Inverters
ZHOU Yue-qing,WANG Hong-jun.Swept-Frequency Start Circuit for Parallel Inverters[J].Industrial Furnace,2007,29(1):34-36.
Authors:ZHOU Yue-qing  WANG Hong-jun
Abstract:In order to overcome a difficulty in starting parallel inverter power supplies,a swept-frequency start circuit with separate and self-excitation is put forward.Questions related to the starting process are analyzed in detail,and simulation results are presented.A 50 kW prototype power supply was developed by using a swept-frequency start circuit for the parallel inverter.Experimental results show that over a frequency range of 18 kHz to 38 kHz,the inverter can start successfully,and this new strategy has a wide swept-frequency range(20 kHz) and a high successful-start ratio(>95%).