1 000 MW机组引风机变频改造扭振的分析
引用本文:陈伟.1 000 MW机组引风机变频改造扭振的分析[J].中国电力,2016,49(6):61-66.
作者姓名:陈伟
作者单位:上海电力股份有限公司,上海 200010
摘    要:为找出引风机联轴器膜片断裂和中间轴裂纹的根本原因,通过对风机不同工况下扭振、扭矩、瓦振等过程参数的测量和频谱分析,确定风机变频运行产生扭振是轴系损坏的根本原因。通过对风机轴系建模仿真,找出了诱发扭振产生的原因和解决途径,为电厂提出了改进建议。

关 键 词:1000MW机组  引风机  变频  轴系  扭振  频谱分析  
收稿时间:2016-02-15
修稿时间:2016-06-16

Analysis on Torsional Vibration Caused by IDF Frequency Conversion in 1 000-MW Unit
CHEN Wei.Analysis on Torsional Vibration Caused by IDF Frequency Conversion in 1 000-MW Unit[J].Electric Power,2016,49(6):61-66.
Authors:CHEN Wei
Affiliation:Shanghai Electric Power Co., Ltd., Shanghai 200010, China
Abstract:The measurement and spectrum analysis are taken on the process parameters of the fan, such as torsional vibration, torque and bearing vibration, under different conditions to find out the root causes of fan diaphragm coupling fracture and intermediate shaft crack. With the analysis, it is determined that the fan frequency conversion operation causes the torsional vibration and it is the root cause for the damage of the shafting system. Based on the fan shafting system modeling and simulation, the causes and solutions are figured out and suggestions for improvement are put forward.
Keywords:1 000-MW unit  induced draft fan (IDF)  frequency conversion  shafting  torsional vibration  frequency spectrum analysis  