首页 | 官方网站   微博 | 高级检索  
     

影响汽包差压水位计测量的几种常见因素及排除方法
引用本文:闫建军,吕福祉.影响汽包差压水位计测量的几种常见因素及排除方法[J].华北电力技术,2006(A02):72-74.
作者姓名:闫建军  吕福祉
作者单位:山西大唐国际云冈热电有限责任公司,山西大同037039
摘    要:大多数火电厂汽包水位的测量都是采用差压水位计作为主要监测手段,为此介绍了引起差压水位计测量误差的几种常见因素,及针对这些常见因素所采取的方法。

关 键 词:汽包差压水位计  误差  因素  反措
收稿时间:2006-06-07

Common Factors Influencing Drum Differential-pressure Water Level Indicators Measuring and Countermeasures
Yan Jian-jun,Lv Fu-zhi.Common Factors Influencing Drum Differential-pressure Water Level Indicators Measuring and Countermeasures[J].North China Electric Power,2006(A02):72-74.
Authors:Yan Jian-jun  Lv Fu-zhi
Affiliation:Shanxi Datang International Yungang Thermal Power Co. Ltd. ,Datong 037039,China
Abstract:Differential-pressure water level indicators are now in common use in fossil-fuel power plant. Therefore the common origins of the measuring errors of differential-pressure water level indicators are introduced,and the common countermeasures are discussed.
Keywords:drum differential-pressure water level indicators  errors  factors  countermeasures
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号