首页 | 官方网站   微博 | 高级检索  
     

空压机电机进口自耦变压器烧毁的处理
引用本文:张士刚.空压机电机进口自耦变压器烧毁的处理[J].深冷技术,2010(4):57-58.
作者姓名:张士刚
作者单位:南京钢铁联合有限公司气体供应公司,江苏省南京市大厂区210035
摘    要:南钢联气体供应公司1#20000 m3/h空分设备配套空压机的电机采用进口自耦变压器降压启动,自耦变压器运行时因绝缘被击穿而突然烧毁,导致空分设备停车。用国产自耦变压器替代进口自耦变压器,彻底解决了自耦变压器启动问题,保证了空分设备安全稳定运行。

关 键 词:离心压缩机  电机  自耦变压器  烧毁

Treatment of burnt-out of imported autoconnected transformer of air compressor motor
Zhang Shigang.Treatment of burnt-out of imported autoconnected transformer of air compressor motor[J].Cryogenic Technology,2010(4):57-58.
Authors:Zhang Shigang
Affiliation:Zhang Shigang (Gas Supply Company, Nanjing Iron & Steel United Co., Ltd., Dachang District, Nanjing 210035, Jiangsu, P. R. China)
Abstract:The motor of air compressor of 1#20000 m^3,/h air separation plant of Nanjing Iron & Steel United Co. , Ltd. , Gas Supply Company is started through reduced-voltage with autoeonnected transformer. The said transformer is abruptly burnt out due to breaking down of the insulation during operation, which results in shutdown of the air separation plant. Substitution of domestic-made autoconnected transformer for the imported one completely solves the problems in start and ensures safe and stable run of the air separation plant.
Keywords:Centrifugal compressor  Motor  Autoconnected transformer  Burn-out
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号