摘    要:为实现地震后结构性能快速恢复,针对设置开缝钢板阻尼器的震后可恢复功能摇摆(ERR)柱技术,采用增加螺栓数量以减小连接板与钢板阻尼器端部局部滑移的方法对该技术予以改进.为进一步研究改进后ERR柱的受力特性及性能可恢复性,完成了 8个足尺试件的低周往复加载试验,主要研究轴压比、钢板阻尼板厚度和阻尼器数量等对试件抗震性能的影...

关 键 词:可恢复功能防震结构  摇摆柱  可更换开缝钢板阻尼器  拟静力试验  抗震性能

Experimental study on seismic performance of earthquake resilient rocking column
LIU Xiaojuan,LIU Yang,HUANG Zewei,XU Yipeng,GUO Zixiong. Experimental study on seismic performance of earthquake resilient rocking column[J]. Journal of Building Structures, 2021, 42(8): 204-212. DOI: 10.14006/j.jzjgxb.2018.0711
Authors:LIU Xiaojuan  LIU Yang  HUANG Zewei  XU Yipeng  GUO Zixiong
Affiliation:1. College of Civil Engineering, Huaqiao University, Xiamen 361021,  China;2. Key Laboratory for Structural Engineering and Disaster Prevention of Fujian Province, Huaqiao University, Xiamen 361021, China
Abstract:In order to achieve structural resilience after earthquakes, based on the earthquake resilient rocking (ERR) column technology with steel slit dampers, the ERR column was improved by increasing the number of bolts to reduce the local slippage between the end of steel slit damper and the connecting plate. To further study the mechanical properties and the performance resilience of the improved ERR column, the quasi-static tests on eight full-scaled ERR columns were carried out. The influences of axial compression ratio, plate thickness, and the number of steel slit dampers on the seismic performance of ERR columns were studied. It is indicated that, with the ‘strong-column/weak-damper’ design philosophy, the plastic deformation of ERR columns under major earthquake would be concentrated on the replaceable steel slit dampers. Stable hysteretic performance of ERR columns are achieved. The horizontal load carrying capacity of ERR columns increases with the increase of the axial compression ratio and damper thickness. By adding two steel slit dampers at the bottom of the column perpendicular to the loading direction, the lateral load carrying capacity and ultimate deformation of ERR columns are increased by 11% and 14%, respectively.
Keywords:earthquake resilient structure   rocking column   replaceable steel slit damper   quasi-static test  seismic performance  