预应力纤维布加固混凝土圆形截面短柱轴压性能试验
引用本文:周长东,白晓彬,赵锋,吕西林,厉春龙.预应力纤维布加固混凝土圆形截面短柱轴压性能试验[J].建筑结构学报,2013,34(2):131-140.
作者姓名:周长东  白晓彬  赵锋  吕西林  厉春龙
作者单位:1.北京交通大学 土木建筑工程学院, 北京 100044; 2.同济大学 土木工程防灾国家重点实验室, 上海 200092;3.中冶建筑研究总院, 北京 100088
基金项目:国家自然科学基金面上项目(50978021);同济大学土木工程防灾国家重点实验室开放基金项目(SLDRCE08-MB-01);中央高校基本科研业务费项目(2011JBM080)
摘    要:为研究环向预应力纤维布加固混凝土圆形截面短柱的轴心受压性能,制作25个试件并进行轴心受压试验。试验考虑的影响因素包括:试件的混凝土强度等级、截面尺寸、箍筋间距、既有损伤及表面处理情况、纤维布种类、层数和预应力大小。试验得到了各个试件的破坏形态和应力 应变关系,进而分析了各影响因素对加固效果的影响。结果表明:与非加固试件相比,环向预应力纤维布加固试件的轴心受压承载力和延性均有明显提高;对纤维布施加预应力能避免纤维布的应力滞后,更好地发挥纤维布的高强性能;当环向预应力与纤维布的抗拉强度的比值在0~0.20范围内,试件的承载力和延性随预应力的增大而增大;当环向预应力达到纤维布抗拉强度的0.25倍时加固效果会降低,因此在工程应用中环向纤维布的预应力宜控制在纤维布抗拉强度的0~0.20倍之间。

关 键 词:环向预应力  混凝土圆形截面柱  静力试验  纤维布加固  轴压性能  

Experimental study on circular concrete short columns strengthened with pre-stressed FRP under axial compression
ZHOU Changdong,BAI Xiaobin,ZHAO Feng,LU Xilin,LI Chunlong.Experimental study on circular concrete short columns strengthened with pre-stressed FRP under axial compression[J].Journal of Building Structures,2013,34(2):131-140.
Authors:ZHOU Changdong  BAI Xiaobin  ZHAO Feng  LU Xilin  LI Chunlong
Affiliation:1.School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China;; 2.State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China;3.Central Research Institute of Building and Construction, Beijing 100088, China
Abstract:To study the axial compressive performance of circular concrete short columns strengthened with lateral pre-stressed fiber reinforced polymer (FRP), 25 specimens were manufactured and tested under axial compression. The main factors considered in the experiment included concrete strength, cross section size, spacing of stirrup, initial damage and surface treatment of the specimens, pre-stressing level, type and layers of FRP. The failure mode and the stress-strain curve of each specimen were obtained from the experiment and the impact on confining effect of various factors was analyzed. Experimental results show that the strength and ductility of circular concrete columns strengthened with lateral pre-stressed FRP can be improved significantly relative to the un-strengthened specimen, the stress hysteresis of lateral FRP can be avoided by pre-stressing, and the high strength of FRP can be better used. When the pre-stressing of lateral FRP within 0~0.20 times of its ultimate tensile strength, the strength and ductility of specimens increase with the increase of lateral FRP’s pre-stressing. The strengthening effect will be reduced when the pre-stressing of lateral FRP reacheds 0.25 times of its ultimate tensile strength. So the pre-stressing of lateral FRP should be controlled within 0~0.20 times of its ultimate tensile strength in practice.
Keywords:axial compressive behavior  lateral pre-stressing  static test  strengthened with FRP  circular concrete column  