首页 | 官方网站   微博 | 高级检索  
     

高能光源储存环及同步加速器屏蔽计算与探讨
引用本文:张震,王雪涛,侯长松,练德幸,朱卫国,陈飞,李玉文.高能光源储存环及同步加速器屏蔽计算与探讨[J].中华放射医学与防护杂志,2021,41(2):146-150.
作者姓名:张震  王雪涛  侯长松  练德幸  朱卫国  陈飞  李玉文
作者单位:国家卫生健康委职业安全卫生研究中心, 北京 102308;中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室, 北京 100088
基金项目:四川省科技厅社会发展重点研发计划(2020YFS0437);四川省卫生健康委员会重点课题(18ZD049)
摘    要:目的验证和探讨在高能同步辐射光源辐射屏蔽计算中半经验公式和蒙特卡罗模拟方法的一致性和适用性。方法分别采用半经验公式和蒙特卡罗模拟独立计算单电子打靶时屏蔽体外产生的周围剂量当量。结果Jenkins半经验公式计算结果与蒙特卡罗模拟结果比值范围为111%~153%,Sakano半经验公式计算结果与蒙特卡罗模拟结果比值为201%。结论对单一屏蔽材料,半经验公式可简单、保守地完成对高能电子加速器的屏蔽计算。对于多种屏蔽材料,宜采用蒙特卡罗模拟方法。

关 键 词:同步辐射  蒙特卡罗模拟  周围剂量当量
收稿时间:2020/1/16 0:00:00

Shielding calculation and discussion on high energy light source storage ring and synchrotron
Zhang Zhen,Wang Xuetao,Hou Changsong,Lian Dexing,Zhu Weiguo,Chen Fei,Li Yuwen.Shielding calculation and discussion on high energy light source storage ring and synchrotron[J].Chinese Journal of Radiological Medicine and Protection,2021,41(2):146-150.
Authors:Zhang Zhen  Wang Xuetao  Hou Changsong  Lian Dexing  Zhu Weiguo  Chen Fei  Li Yuwen
Affiliation:National Center for Occupational Safety and Health, BHC, Beijing 102308, China;Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China
Abstract:Objective To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source. Methods The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding. Results The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%. Conclusions For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used.
Keywords:Synchrotron radiation  Monte Carlo simulation  Ambient dose equivalent
本文献已被 维普 等数据库收录!
点击此处可从《中华放射医学与防护杂志》浏览原始摘要信息
点击此处可从《中华放射医学与防护杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23