Effect of a Device-Free Compressed Shell Fixation Method on Hepatic Respiratory Movement: Analysis for Respiratory Amplitude of the Liver and Internal Motions of a Fiducial Marker
Authors:Shingo Hashimoto  Masaki Katsurada  Rie Muramatsu  Kumiko Asai  Kenichiro Tanaka  Kensuke Hayashi  Yoshiaki Kibe  Koichiro Nakajima  Yukiko Hattori  Hiromitsu Iwata  Jun-etsu Mizoe  Hiroyuki Ogino  Yuta Shibamoto
Affiliation:1. Department of Radiation Oncology, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya, Japan;2. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan;3. Department of Proton Therapy Technology, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya, Japan;4. Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya, Japan;5. Osaka Heavy Ion Therapy Center, Osaka, Japan
Abstract:

Purpose

Suppression of respiratory movement of the liver would be desirable for high-precision radiation therapy for liver tumors. We aimed to investigate the effect of our original device-free compressed shell fixation method and breathing instruction on suppression of respiratory movement. The characteristics of liver motion based on the movement of a fiducial marker were also analyzed.

Methods and Materials

First, respiratory amplitudes of the liver with the device-free compressed shell were analyzed from the data of 146 patients. The effect of this shell fixing method on liver movement was evaluated. Second, as another cohort study with 166 patients, interfractional internal motion of the liver for patients fixed in the shell was calculated using the fiducial marker coordinate data of images for position setting before daily irradiation. Third, in another 12 patients, intrafractional internal motion was calculated from the fiducial marker coordinate data using x-ray images before and after irradiation.

Results

The median respiratory movement without the shell, after fixing with the shell, and after instructing on the breathing method with the shell was 14.2 (interquartile range, 10.7-19.8), 11.5 (8.6-17.5), and 10.4 mm (7.3-15.8), respectively. Systematic and random errors of interfractional internal motion were all ≤2 mm in the left-right and anteroposterior directions and 3.7 and 3.0 mm, respectively, in the craniocaudal direction. Systematic and random errors of intrafractional internal motion were all ≤1.3 mm in the left-right and anteroposterior directions and 0.8 and 2.4 mm, respectively, in the craniocaudal direction.

Conclusions

The device-free compressed shell fixation method was effective in suppressing the respiratory movement of the liver. Irradiation position matching using the fiducial marker can correct the interfractional internal motion on each day, which would contribute to the reduction of the margin to be given around the target.
Keywords:Corresponding author  Department of Radiation Oncology  Nagoya Proton Therapy Center  Nagoya City West Medical Center  1-1-1 Hirate-cho  Kita-ku  Nagoya 462-8508  Japan  