首页 | 官方网站   微博 | 高级检索  
     


Parametrical static analysis on group studs with typical push-out tests
Affiliation:1. School of Civil Engineering, Tianjin University, Tianjin 300072, China;2. Key Laboratory of Coast Civil Structure and Safety of Ministry of Education, Tianjin University, Tianjin 300072, China;1. Chang''an University, Highway School, Xi''an, Shaanxi 710064, China;2. University of Waterloo, Civil and Environmental Engineering, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada;1. Seokyeong University, 16-1 Jungneung-Dong, Sungbuk-gu, Seoul 136-704, Korea;2. Korea Institute of Civil Engineering and Building Technology, 283 Goyangdae-ro, Ilsangseo-gu, Goyang-si, Gyeonggi-do 411-712, Korea;3. Woosuk University 66 Daehak-ro, Jincheon-eup, Chungcheongbuk-do 365-803, Korea;4. Korea Railroad Research Institute, 176 Cheoldobangmulgwan-ro, Uiwang-si, Gyeonggi-do 437-757, Korea
Abstract:Group studs are known as shear connectors in steel and concrete composite structures. By now, many composite bridges have been characterized by long lateral cantilevers. The shear studs are actually under biaxial action consisting of shear force and action in light of lateral bending moment on concrete slab induced by long cantilever and passing by moving loads. Moreover, lateral bending moment may even lead to the initiation of bending-induced concrete cracks. These two situations can both affect mechanical performance of group studs. Thus, a parametrical FEM analysis was carried out, in which damage plasticity was introduced to simulate material nonlinear behavior. In the analysis, lateral bending moments respectively inducing maximum concrete crack widths of 0.1 mm and 0.2 mm, shank diameters of 13 mm, 16 mm, 19 mm and 22 mm and stud heights including 80 mm and 100 mm were parameters. It was found that mechanical behavior of group studs with large shank diameter would be less affected by biaxial action and initial bending-induced concrete cracks seemed unfavorable to stud shear stiffness. On the other hand, typical push-out tests were executed to investigate reductions of shear stiffness and shear capacity of group studs. The reliability of FEM analysis was also verified based on the tests. In addition, stud shear capacity evaluations according to several design specifications were presented. It indicated shear capacity evaluation of Eurocode 4 got a relatively large safety factor. Moreover, the applicability of these specifications for group studs on shear capacity evaluation was also discussed.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号