首页 | 官方网站   微博 | 高级检索  
     


Fast microwave detection system for coherent synchrotron radiation study at KEK: Accelerator test facility
Authors:A Aryshev  S Araki  P Karataev  T Naito  N Terunuma  J Urakawa
Affiliation:

aDepartment of Accelerator-Science, School of High Energy Accelerator Science, Graduate University for Advanced Studies, Shonan International Village, Hayama, Miura, Kanagawa 240-0193, Japan

bHigh Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan

cJohn Abrams Institute at Royal Holloway, University of London, Egham, Surrey TW20 0EX, UK

Abstract:A fast room temperature microwave detection system based on the Schottky Barrier-diode detector was created at the KEK ATF (Accelerator Test Facility). It was tested using Coherent Synchrotron Radiation (CSR) generated by the 1.28 GeV electron beam in the damping ring. The speed performance of the detection system was checked by observing the CSR from a multi-bunch (2.8 ns bunch separation time) beam. The theoretical estimations of CSR power yield from an edge of bending magnet as well as new injection tuning method are presented. A very high sensitivity of CSR power yield to the longitudinal electron distribution in a bunch is discussed.
Keywords:Coherent synchrotron radiation  Beam diagnostics  Fast detection systems
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号