首页 | 官方网站   微博 | 高级检索  
     

空间约束钢-混凝土组合楼盖抗火性能试验研究
引用本文:张大山,张建春,王慧青,董毓利,王卫华,李艳艳.空间约束钢-混凝土组合楼盖抗火性能试验研究[J].建筑结构学报,2022,43(2):52-64.
作者姓名:张大山  张建春  王慧青  董毓利  王卫华  李艳艳
作者单位:1. 华侨大学 土木工程学院, 福建厦门 361021; 2. 厦门工学院 建筑与土木工程学院, 福建厦门 361021; 3. 河南中原公路勘察设计有限公司, 河南濮阳 457000
基金项目:国家自然科学基金项目(51778250);;福建省自然科学基金项目(2019J01051);;福建省中青年教师教育科研项目(JAT190949);
摘    要:整体结构中钢-混凝土组合楼盖的抗火性能和与其直接相连的周边部件提供的约束力关系密切,但以往研究中却难以获得约束力的真实大小.为此,设计了空间约束钢框架,用以模拟真实结构中钢-混凝土组合楼盖的边界条件,同时可测得约束力的大小.通过开展带空间约束框架的钢-混凝土组合楼盖的受火试验,获得了组合楼盖的裂缝发展过程、破坏特征、温...

关 键 词:钢-混凝土组合楼盖  空间约束  受火试验  翘曲力  抗火性能

Experimental study on behavior of steel-concrete composite floor with spacial restraints subjected to fire
ZHANG Dashan,ZHANG Jianchun,WANG Huiqing,DONG Yuli,WANG Weihua,LI Yanyan.Experimental study on behavior of steel-concrete composite floor with spacial restraints subjected to fire[J].Journal of Building Structures,2022,43(2):52-64.
Authors:ZHANG Dashan  ZHANG Jianchun  WANG Huiqing  DONG Yuli  WANG Weihua  LI Yanyan
Affiliation:1. College of Civil Engineering, Huaqiao University, Xiamen 361021, China; 2. College of Architecture and Civil Engineering, Xiamen Institute of Technology, Xiamen 361021, China; 3. Henan Zhongyuan Highway Survey and Design Company, LTD, Puyang 457000, China;
Abstract:Fire resistance of steel-concrete composite floor in an overall structure has a direct relationship to its restraint forces provided by the surrounding structural elements,but it is very difficult to measure the corresponding restraint forces.In order to simulate the real edge restraint condition and to obtain the value of restraint forces,a new device,mainly composed of a spatial steel-frame structure,was designed and fabricated with the steel-concrete composite floor in this paper.A fire test was conducted on the steel-concrete composite floor with spatial restraints to observe the development of cracks and to explore the final failure modes.In addition,the temperature field,vertical and horizontal displacements,rotational angle and restraint forces at the corner of the slab,were all collected during the test.It is shown that the fire-resistance time of the steel-concrete composite floor is 300 min,at which moment the temperature on the slab surface reaches 180℃,so indicating that thermal insulation is compromised.The testing data indicated that the maximum vertical displacement,105.8 mm,is approximately 1/34 of the length of the shorter span.A strong displacement-recover phenomenon occurrs at the cooling stage,with a ratio of as high as 47.8%,and this phenomenon is due to the strength recovery of the steel secondary beam under the slab.The effect of restraint forces at the corner of steel-concrete composite floor is obvious,and the restraining action includes the restraint moments and warping forces.The warping forces are significant and have an inverse variation range at the elevated and cooling stage,and it could be a potential hazard to the columns at the adjacent storey.
Keywords:steel-concrete composite floor  spacial restraint  fire test  warping force  fire-resistance performance
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号