摘    要:重庆市主城区核心地段某污水处理厂面对急需提标扩能以及日益突出的"厂群"矛盾等多重难题,在无法迁建扩建的情况下,利用重庆市山地地形特点,改造为半地下式污水处理厂,在不增加用地的情况下,实现了原址提一级A标准和扩能1.2×104 m3/d,并在上部修建市民广场和综合办公大楼,吨水用地为0.36 m2/(m3·d),远低于国...

关 键 词:提标扩能  原址改建  前置反硝化  两级曝气生物滤池  地下污水处理厂  单位用地指标

Upgrading and Capacity Expansion of Existing WWTP in Core Urban Area of Chongqing City
YANG Renkai,ZHANG Hua,ZHANG Shuang,DONG Lichun.Upgrading and Capacity Expansion of Existing WWTP in Core Urban Area of Chongqing City[J].Water Purifcation Technology,2022,41(2):139-143.
Authors:YANG Renkai  ZHANG Hua  ZHANG Shuang  DONG Lichun
Affiliation:(School of Chemistry and Chemical Engineering,Chongqing University,Chongqing 400044,China;Chongqing Drainage Co.,Ltd.,Chongqing 400020,China;Chongqing Three Gorges Water Service Co.,Ltd.,Chongqing 400020,China)
Abstract:A wastewater treatment plant(WWTP)in the core area of Chongqing city is facing many problems,such as urgent need to raise standards,expand capacity,and the increasingly prominent contradiction of"plant group".It is impossible to move and expand,the semi-underground WWTP is transformed by taking advantage of the mountainous terrain characteristics of Chongqing city.Without increasing land use,original site is upgraded to first grade A cretiria and the capacity is expanded by 1.2×104m3/d.Citizen square and comprehensive office building are built on the upper part.The land use per ton of water is 0.36 m2/(m3·d),which is far lower than that of national and industrial WWTP of same scale0.95~1.20 m2/(m3·d)].The space resource utilization and environmentfriendly optimization are realized.The selection and design of a two-stage biological aerated filter(BAF)process with presedimentation tank and pre-denitrification and nitrification functions,and main process design parameters are introduced in this paper,while operate one year after the environmental protection acceptance,effluent quality is stable and superior to the first class A criteria of Discharge Standard of Pollutants for Municipal Treatment Plant(GB 18918—2002),which provides reference for similar engineering cases.
Keywords:upgrading and expansion  in-situ reconstruction  pre-denitrification  two-stage BAF  underground WWTP  unit land use index