首页 | 官方网站   微博 | 高级检索  
     

交直流电压条件下TVS触发特性研究
引用本文:范兴明,张鑫,杨家志,樊建荣,潘永成,黄知超,李震,刘华东.交直流电压条件下TVS触发特性研究[J].真空科学与技术学报,2012,32(6):477-482.
作者姓名:范兴明  张鑫  杨家志  樊建荣  潘永成  黄知超  李震  刘华东
作者单位:1. 桂林电子科技大学机电工程学院 桂林 541004
2. 桂林理工大学信息科学与工程学院 桂林541004
3. 日升集团有限公司 浙江 315700
基金项目:国家自然科学基金项目(51067002;5116704);广西省教育厅科研项目(201010LX105;201106LX157;201106LX218)
摘    要:通过试验得到了触发系统的触发能量、触发电压与真空触发开关(TVS)导通概率、触发时延及分散性的关系,试验结果可以作为高性能真空触发开关控制器的设计与应用的指导。触发点火回路采用陡化高压触发脉冲,使TVS的导通时延及其分散性显著降低。引入同步触发技术,控制TVS主间隙在交流外施电压峰值触发。重点比较主间隙施加交直流情况下的触发特性,在触发参数、交流电压峰值与直流电压值相等的条件下,直流情况下TVS的导通概率和触发稳定性明显高于交流情况,交流情况下对触发系统的要求更为苛刻。

关 键 词:真空触发开关  交流负荷  触发特性  控制器  实验研究

Triggering Characteristics of Triggered Vacuum Switch under AC and DC Loads
Fan Xingming , Zhang xin , Yang Jiazhi , Fan Jianrong , Pan yongchen , Huang Zhichao , Li zhen , Liu Hua-dong.Triggering Characteristics of Triggered Vacuum Switch under AC and DC Loads[J].JOurnal of Vacuum Science and Technology,2012,32(6):477-482.
Authors:Fan Xingming  Zhang xin  Yang Jiazhi  Fan Jianrong  Pan yongchen  Huang Zhichao  Li zhen  Liu Hua-dong
Affiliation:1(1.Guilin University of Electronic Technology,Guilin 541004,China;2.Guilin University of Technology,Guilin 541004,China;3.SUNRISE GROUP Corporation,Zhejiang 315700,China)
Abstract:The relationship between the triggering parameters,including the triggering voltage and power,and the triggering characteristics,such as the triggering-time delay,triggering probability,and scattering of the triggered vacuum switches(TVS) under AC and DC loads,were experimentally evaluated.The high-voltage pulse,generated by the main high-voltage circuit,is capable of considerably shortening the triggering-time delay,and reducing the scattering of the TVS;and the synchronous triggering technology make it possible to control the triggering phase at the peak of the external AC voltage at the main gap of the TVS.With the identical triggering parameters,and with the AC voltage amplitude being equal to DC voltage,the triggering probability and stability of the DC loaded TVS were found to be much better than those of the AC loaded TVS.Triggering of the AC loaded TVS needs more stringent requirements.
Keywords:TVS  AC load  Triggering characteristic  Controller  Experiment research
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23