首页 | 官方网站   微博 | 高级检索  
     

MEIA法与ELISA法检测26例血清HBsAg和HBeAg的比较
引用本文:李梦华.MEIA法与ELISA法检测26例血清HBsAg和HBeAg的比较[J].中国医药导报,2008,5(36):80-81.
作者姓名:李梦华
作者单位:辽宁省大连市第六人民医院检验科,辽宁大连,116000
摘    要:目的:比较微粒子酶免疫分析法(MEIA)与酶联免疫吸附试验(ELISA)法检测血清HBsAg和HBeAg的差异。方法:选择26例经ELISA法检测已确定乙肝五项中HBsAg阴性而HBeAg和HBcAb阳性(其中7例HBsAb阳性)的患者血清,应用MEIA法再次检测乙肝五项。结果:MEIA法检测结果显示,21例患者血清HBsAg呈现阳性(其中6例HBsAb阳性),1例患者血清HBsAg仍呈现阴性(其HBsAb阳性),4例患者血清HBsAg和HBeAg均呈现阴性。结论:MEIA法可减少假阴性、假阳性的发生,优于ELISA法。

关 键 词:酶联免疫吸附试验  微粒子酶免疫分析法  肝炎病毒乙型  假阴性  假阳性

Comparison of MEIA method versus ELISA method for the detecting of HBsAg and HBeAg in the serum samples from 26 patients
LI Meng-hua.Comparison of MEIA method versus ELISA method for the detecting of HBsAg and HBeAg in the serum samples from 26 patients[J].China Medical Herald,2008,5(36):80-81.
Authors:LI Meng-hua
Affiliation:LI Meng-hua (Department of Clinical Laboratory,the Sixth People's Hospital of Dalian,Dalian 116000,China)
Abstract:Objective:To compare the performance of MEIA method and ELISA method by detecting HBsAg and HBeAg in serum samples. Methods: 26 serum samples which had shown HBsAg negative while HBeAg and HBcAb positive (7 samples of them were HBsAb positive) confirmed by ELISA method were re-tested with MEIA method. Results: 21 samples showed HBsAg positive (6 samples of them were HBsAb positive), 1 sample still showed HBsAg negative (HBsAb was positive), and 4 samples showwed both HBsAg and HBeAg negative. Conclusion: MEIA method is more precise than ELISA method due to its less incidences in false positive and false negative.
Keywords:ELISA  MEIA  HBV  False negativity  False positivity
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号