首页 | 官方网站   微博 | 高级检索  
     

金属封闭式开关柜绝缘在线检测
引用本文:袁世平.金属封闭式开关柜绝缘在线检测[J].东北电力技术,2012,33(9):45-46,49.
作者姓名:袁世平
作者单位:浙江省天台县供电局,浙江 台州,317200
摘    要:通过对金属封闭式开关柜结构及绝缘故障类型的分析,认为测量开关柜内部局部放电和过热可对开关柜绝缘故障进行预警,并提出在开关柜顶部装设超声局放检测装置,在内壁装设光纤测温装置,可实现开关柜绝缘在线检测。

关 键 词:金属封闭式开关柜  绝缘  局部放电  过热  检测

Insulation Live Testing for Enclosed Metal Switchgear
YUAN Shi-ping.Insulation Live Testing for Enclosed Metal Switchgear[J].Northeast Electric Power Technology,2012,33(9):45-46,49.
Authors:YUAN Shi-ping
Affiliation:YUAN Shi-ping (Tiantai Power Supply Bureau, Taizhou, Zhejiang 317200, China)
Abstract:In this paper, the structure of the enclosed metal switchgear and the types of the insulation fault is analyzed. By measuring the internal partial discharge switchgear and switchgear overheating, the insulation failure can be early warned. By putting the ultra sonic PD detector device at the top of the switchgear and by installing the temperature measuring device on the inside walls, the insula tion live testing can be achieved.
Keywords:Enclosed metal switehgear  Insulation  Partial discharge  Overheating  detection