首页 | 官方网站   微博 | 高级检索  
     

GeneXpert实时荧光定量PCR在诊断艰难梭菌感染中的临床应用
引用本文:程敬伟,刘畅,肖盟,孙宏莉,王瑶,杨启文,徐英春.GeneXpert实时荧光定量PCR在诊断艰难梭菌感染中的临床应用[J].临床检验杂志,2021,39(1):17-21.
作者姓名:程敬伟  刘畅  肖盟  孙宏莉  王瑶  杨启文  徐英春
作者单位:首都医科大学附属北京友谊医院检验科,北京 100050;清华大学附属华信医院检验科,北京 100016;中国医学科学院北京协和医院检验科,北京100730
基金项目:首都医科大学附属北京友谊医院 “种子计划”人才项目(YYZZ2018B01)。
摘    要:目的评价Gene Xpert实时荧光定量PCR法在诊断艰难梭菌感染中的应用价值。方法收集住院腹泻患者非重复粪便标本296份,同时进行Gene Xpert试验和产毒素培养(toxigenic culture,TC)。TC包括厌氧培养、菌株基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)鉴定、PCR扩增艰难梭菌毒素基因。以TC结果为参考,评价Gene Xpert试验的敏感性、特异性、阳性预测值、阴性预测值,并评价Gene Xpert试验和TC 2种方法结果的一致性。结果 Gene Xpert试验的敏感性、特异性、阳性预测值和阴性预测值分别为98.5%、92.6%、91.7%和98.7%。Gene Xpert试验与TC一致性好(Kappa=0.905)。Gene Xpert试验报告2株RT027型高毒力菌株,经核糖体分型确证为RT027型艰难梭菌。结论 Gene Xpert实时荧光定量PCR可快速、准确检测粪便标本中的艰难梭菌毒素基因,且可报告高毒力RT027型菌株,具有重要的临床应用价值。

关 键 词:艰难梭菌  GeneXpert  毒素
收稿时间:2020/10/24 0:00:00

Clinical application of GeneXpert real-time fluorescence quantitation PCR in the diagnosis of Clostridium difficile infection
CHENG Jingwei,LIU Chang,XIAO Meng,SUN Hongli,WANG Yao,YANG Qiwen,XU Yingchun.Clinical application of GeneXpert real-time fluorescence quantitation PCR in the diagnosis of Clostridium difficile infection[J].Chinese Journal of Clinical Laboratory Science,2021,39(1):17-21.
Authors:CHENG Jingwei  LIU Chang  XIAO Meng  SUN Hongli  WANG Yao  YANG Qiwen  XU Yingchun
Affiliation:(Center of Clinical Labora tory,Beijing Friendship Hospital,Capital Medical University,Beijing 100050;Department of Clinical Laboratory,Beijing Huaxin Hospital,the First Affiliated Hospital of Tsinghua University,Beijing 100016;Department of Clinical Laboratory,Peking Union Med ical College Hospital,Chinese Academy of Medical Sciences,Beijing 100730,China)
Abstract:Objective To evaluate the application value of Gene Xpert real-time fluorescence quantitation PCR( Gene Xpert PCR) in the diagnosis of Clostridium difficile infection. Methods A total of 296 unrepeated stool specimens were collected from the diarrhea inpatients,and toxigenic culture( TC) and Gene Xpert PCR were performed,respectively. For TC,after anaerobic culture,bacterial clones were identified by the matrix-assisted laser desorption/ionization time of flight mass spectrometry( MALDI-TOF MS) and the toxin genes of Clostridium difficile were detected by PCR. Taking TC results as a reference,the sensitivity,specificity,positive predictive value and negative predictive value of Gene Xpert PCR and the consistency of the results between Gene Xpert PCR and TC were evaluaed. Results The sensitivity,specificity,positive predictive value and negative predictive value of Gene Xpert PCR were 98.5%,92.6%,91.7% and 98. 7%,respectively,and there was good consistency between TC and Gene Xpert PCR( Kappa = 0. 905). Two strains of RT027 with high virulence were detected by Gene Xpert PCR,and were confirmed as RT027 type Clostridium difficile by Ribotyping. Conclusion Gene Xpert real-time fluorescence quantitation PCR is able to detect the toxin genes of Clostridium difficile in stool specimens rapidly and accurately,and able to identify the RT027 strains with high virulence,which has important clinical application value.
Keywords:Clostridium difficile  GeneXpert  toxin
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《临床检验杂志》浏览原始摘要信息
点击此处可从《临床检验杂志》下载全文