首页 | 官方网站   微博 | 高级检索  
     


Expedient liquid chromatographic method with fluorescence detection for montelukast sodium in micro-samples of plasma
Authors:Sameer Al-Rawithi  Sulaiman Al-Gazlan  Wijdan Al-Ahmadi  Ibrahim A Alshowaier  Ahmed Yusuf  Dale A Raines
Abstract:This study describes an expedient assay for the analysis of the asthma medication, montelukast sodium (Singulair, MK-0476), in human plasma samples. After a simple extraction of the plasma, the drug and internal standard, quinine bisulfate, were measured by HPLC. The chromatographic system consisted of a single pump, a refrigerated autosampler, a C8 4-μm particle size radial compression cartridge at 40°C and a fluorescence detector with the excitation and emission wavelengths set at 350 and 400 nm, respectively. The mobile phase which was delivered at 1.0 ml/min, was prepared by adding 200 ml of 0.025 M sodium acetate, pH adjusted to 4.0 with acetic acid, to 800 ml of acetonitrile, with 50 μl triethylamine. With a run time of only 10 min per sample, this assay had an overall recovery of >97% with a detection limit of 1 ng/ml. The inter- and intra-run relative standard deviations at 0.05, 0.2 and 1.0 μg/ml were all <9.2%, while the analytical recovery at the same concentrations were within 7.7% of the amount added.
Keywords:Montelukast sodium
本文献已被 ScienceDirect 等数据库收录!