首页 | 官方网站   微博 | 高级检索  
     


Benchmarking of JEFF-3.2, FENDL-3.0 and TENDL-2014 evaluated data for tungsten with 14.8 MeV neutrons
Authors:Suyalatu Zhang  Yang-Bo Nie  Jie Ren  Fei Luo  Xi-Chao Ruan  Zhi-Qiang Chen  Rui Han  Temuerbagen Bao  Si-Miao Ge
Affiliation:1. College of Physics and Electronics Information, Inner Mongolia University for the Nationalities, Tongliao 028000,China;2. China Nuclear Data Center, China Institute of Atomic Energy, Beijing 102413, China;3. Institute of Modern Physics, Chinese Academy of Sciences,Lanzhou 730000, China;4. School of Chemical Engineering, Sichuan University,Chengdu 610065, China
Abstract:Integral experiments on tungsten slab samples were carried out on the D-T neutron source facility at China Institute of Atomic Energy.Leakage neutron spectra from the irradiated tungsten target were measured by the time-of-flight technique.Accuracy of the nuclear data for tungsten was examined by comparing the measured neutron spectra with the leakage neutron spectra simulated using the MCNP-4C code with evaluated nuclear data of the JEFF-3.2,FENDL-3.0 and TENDL-2014 libraries.The results show that the calculations with JEFF-3.2 agree well with the measurements in the whole energy range and all angles,whereas the spectra calculated with FENDL-3.0 and TENDL-2014 have some discrepancies with the experimental data.
Keywords:Integral experiment  D-T neutron source  Time-of-flight technique  Leakage neutron spectrum  Monte Carlo simulation  Evaluated nuclear data
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号