首页 | 官方网站   微博 | 高级检索  
     

矩形截面微通道内气-液两相流压力降的实验测定及关联(英文)
引用本文:马友光,季喜燕,王东继,付涛涛,朱春英.矩形截面微通道内气-液两相流压力降的实验测定及关联(英文)[J].中国化学工程学报,2010,18(6):940-947.
作者姓名:马友光  季喜燕  王东继  付涛涛  朱春英
作者单位:School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University, Tianjin 300072, China
基金项目:Supported by the National Natural Science Foundation of China (20876107);the Opening Project of State Key Laboratory of Chemical Engineering (SKL-ChE-08B06)
摘    要:The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water,ethanol and n-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm× 200 μm,100 μm× 400 μm,100 μm× 800 μm and 100 μm× 2000 μm(depth × width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale,the capillary number also affected the pressure drop remarkably,and in spite of only one-fold difference in aspect ratio,the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account,a modi-fied correlation for Chisholm parameter C in the Chisholm model was proposed for predicting the frictional multi-plier,and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data.

关 键 词:pressure  drop  rectangular  cross-section  microchannel  surface  tension  configuration  influence  Chisholm  parameter  C  
收稿时间:2010-6-17
修稿时间:2010-6-17  

Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels
Youguang MA, Xiyan JI, Dongji WANG, Taotao FU,Chunying ZHU.Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels[J].Chinese Journal of Chemical Engineering,2010,18(6):940-947.
Authors:Youguang MA  Xiyan JI  Dongji WANG  Taotao FU  Chunying ZHU
Affiliation:School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University, Tianjin 300072, China;School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University, Tianjin 300072, China;School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University, Tianjin 300072, China;School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University, Tianjin 300072, China;School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University, Tianjin 300072, China
Abstract:The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water,ethanol and n-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm×200 μm,100 μm×400 μm,100 μm×800 μm and 100 μm×2000 μm(depth×width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale,the capillary number also affected the pressure drop remarkably,and in spite of only one-fold difference in aspect ratio,the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account,a modified correlation for Chisholm parameter C in the Chisholm model was proposed for predicting the frictional multiplier Φ12,and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data.
Keywords:pressure drop  rectangular cross-section microchannel  surface tension  configuration influence  Chisholm parameter C
本文献已被 CNKI 万方数据 ScienceDirect 等数据库收录!