首页 | 官方网站   微博 | 高级检索  
     

激光散射法和便携式氢火焰离子化检测器法直读监测油烟排放
引用本文:潘光,季海滨,韩志刚,乔椋,郝赛梅,孙友敏,张桂芹.激光散射法和便携式氢火焰离子化检测器法直读监测油烟排放[J].中国环境监测,2021,37(6):206-213.
作者姓名:潘光  季海滨  韩志刚  乔椋  郝赛梅  孙友敏  张桂芹
作者单位:山东省生态环境监测中心, 山东 济南 250101;青岛崂应海纳光电环保集团有限公司, 山东 青岛 266000;山东建筑大学市政与环境工程学院, 山东 济南 250101;山东建筑大学市政与环境工程学院, 山东 济南 250101;山东建筑大学资源与环境创新研究院, 山东 济南 250101
基金项目:济南市科技局自主培养创新团队项目(2020GXRC008)
摘    要:餐饮业油烟排放具有排放浓度不稳定、波动较大、排放时间短等特性,存在瞬时排放高值现象,油烟"看得见"和"闻得着"的问题依然存在,因此对油烟实现快速、及时、直读监测尤为必要。基于一种浓度可控且稳定的油烟产生技术,对直读激光散射法与经典手工称重法测定油烟颗粒物浓度值的数据线性关系进行了分析,发现2种方法数值的相关系数达0.99,通过直读修正激光散射法可以有效地测定油烟颗粒物浓度,并测定了不同水汽含量下油烟颗粒物排放情况,发现当相对湿度超过70%时,油烟颗粒物浓度测定值会发生突变。使用便携式氢火焰离子化检测器法(FID)和光离子化检测器法(PID)测定了不同油温下油烟中非甲烷总烃(NMHC)浓度,发现FID对油烟中NMHC的变化反应及时,能够较好地测定油烟中挥发性有机物的排放量。

关 键 词:油烟排放  激光散射法  非甲烷总烃  便携式氢火焰离子化检测器法  水汽含量
收稿时间:2021/7/10 0:00:00
修稿时间:2021/10/13 0:00:00

Application of Laser Scattering Method and Portable Hydrogen Flame Ionization Detector in Direct Reading Monitoring of Oil Fume Emission
PAN Guang,JI Haibin,HAN Zhigang,QIAO Liang,HAO Saimei,SUN Youmin,ZHANG Guiqin.Application of Laser Scattering Method and Portable Hydrogen Flame Ionization Detector in Direct Reading Monitoring of Oil Fume Emission[J].Environmental Monitoring in China,2021,37(6):206-213.
Authors:PAN Guang  JI Haibin  HAN Zhigang  QIAO Liang  HAO Saimei  SUN Youmin  ZHANG Guiqin
Affiliation:Shandong Provincial Environmental Monitoring Center, Jinan 250101, China;Qingdao Laoying Haina Opto-electronic Environmental Protection Group Co, Ltd, Qingdao 266000, China;Shandong Jianzhu University School of Municipal and Environmental Engineering, Jinan 250101, China; Shandong Jianzhu University School of Municipal and Environmental Engineering, Jinan 250101, China;Shandong Jianzhu University Research Institute of Resources and Environment Innovation, Jinan 250101, China
Abstract:The cooking fume emission has the characteristics of unstable emission concentration,large fluctuation and short emission time,the Peak emissions may exceeding the standard,and the problem of oil fume "visible"and "audible" still exists,so fast,timely and real-time monitoring of oil fume is necessary.In this paper,based on a concentration controllable and stable oil fume generation technology,The linear relationship between the concentration of oil fume particles measured by laser scattering method and classical manual weighing method is analyzed.It is found that the correlation between the two methods is as high as 0.99.The concentration of oil fume particles can be determined effectively by modified laser scattering method.The effect of moisture content on the measurement of oil fume particles is analyzed by laser scattering method.It is found it would cause abrupt changes in the concentration of oil fume particles measured when relative humidity exceeds 70%.The volatileorganic compound emissions from oil fumes at different temperatures were measured by portable hydrogen flame ionization detector (FID),and photoionization detector (PID),through analysising those items,it was found that the FID can better represent the real-time emission change of oil fume and the emission of oil fume organic compound.
Keywords:oil fume emission  laser scattering method  NMHC  portable FID  moisture content
点击此处可从《中国环境监测》浏览原始摘要信息
点击此处可从《中国环境监测》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号