Development of button-type pickup for SSRF ring
Abstract:In building Shanghai Synchrotron Radiation Facility(SSRF), in order to reduce or eliminate the unnecessary sources of beam motion, the precise and stable beam position measurement system in the feedback system was required. In this study, we focused on theoretical analysis of the electrode of beam position monitor(BPM).Simulations, including analytic derivations of the propagation impedance and the distribution inductance, were performed. The BPM was designed based on the results and the acceptance measurements of the impedance and the inductance by using the time domain reflection(TDR) with a network analyzer. It has been proved in years of operations that the BPM system meets the requirement of the resolution of sub-micron.
Keywords:SSRF  BPM  Position sensitivity  Cut-off frequency  Distributed capacitance