首页 | 官方网站   微博 | 高级检索  
     

钢骨混凝土连梁联肢剪力墙抗震性能试验研究及有限元分析
引用本文:周颖,缪驰,闫峰,刘晴云.钢骨混凝土连梁联肢剪力墙抗震性能试验研究及有限元分析[J].建筑结构学报,2015,36(3):36-45.
作者姓名:周颖  缪驰  闫峰  刘晴云
作者单位:1. 同济大学 土木工程防灾国家重点实验室, 上海 200092;; 2. 华东建筑设计研究院有限公司, 上海 200092
基金项目:国家自然科学基金项目(51322803);“十二五”国家科技支撑计划项目(2012BAJ13B02)
摘    要:国内已有部分超高层建筑结构采用钢骨混凝土连梁联肢剪力墙,但现行规范尚未对其钢骨含钢率等控制参数给予明确规定。为此,对不同含钢率的钢骨混凝土连梁联肢剪力墙进行了低周反复荷载试验研究、ABAQUS有限元模拟以及变参数分析。分析结果表明:钢骨混凝土连梁联肢剪力墙试件的破坏模式、水平承载力、变形能力和耗能能力明显优于钢筋混凝土连梁联肢剪力墙;由ABAQUS参数分析结果可知,钢骨含钢率应控制在4%~8%之间,且宜增加连梁钢骨腹板的面积。

关 键 词:抗震性能    拟静力试验  钢骨含钢率  钢骨混凝土  联肢剪力墙  有限元分析  

Experimental study and FEA of seismic performance of coupled shear walls with steel reinforced concrete coupling beams
ZHOU Ying , MIAO Chi , YAN Feng , LIU Qingyun.Experimental study and FEA of seismic performance of coupled shear walls with steel reinforced concrete coupling beams[J].Journal of Building Structures,2015,36(3):36-45.
Authors:ZHOU Ying  MIAO Chi  YAN Feng  LIU Qingyun
Affiliation:1. State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China;2. East China Architectural Design & Research Institute Co., Ltd, Shanghai 200092, China
Abstract:Coupled shear walls with steel reinforced concrete (SRC) coupling beams have recently been applied in practical projects. Nonetheless, no clear requirement is specified in current codes on key parameters such as steel ratio of this technology. This research performed cyclic loading tests on coupled shear walls using SRC coupling beams with variable steel ratio. Finite element analysis with software of ABAQUS and variable parametric analysis were further conducted. The results of experiments and finite element analysis show that better failure mode and higher deformability, energy dissipation capacity and ultimate horizontal bearing capacity of shear walls with SRC coupling beams can be observed than those of shear walls with reinforced concrete (RC) coupling beams. And from the results of finite element analysis with ABAQUS, it can be concluded that the optimal steel ratio in the beams ranges from 4% to 8% and the web area of the steel should be increased.
Keywords:steel reinforced concrete  coupled shear wall  steel ratio  quasi-static test  FEA  seismic performance
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23