首页 | 官方网站   微博 | 高级检索  
     


Discordance between ambulatory monitoring and programmed stimulation in assessing efficacy of class IA antiarrhythmic agents in patients with ventricular tachycardia
Authors:S G Kim  S W Seiden  J A Matos  L E Waspe  J D Fisher
Affiliation:From the Department of Medicine, Division of Cardiology , Arrhythmia Service. Montefiore Medical Center, Montefiore Hospital/Moses Division and the Albert Einstein College of Medicine, Bronx, New York.
Abstract:Concordance between programmed stimulation and 24 hour ambulatory electrocardiographic (Holter) monitoring was studied in 54 patients with sustained ventricular tachycardia during 84 therapeutic trials with class IA antiarrhythmic agents. During baseline studies before treatment, all patients had frequent (greater than or equal to 30/h) ventricular premature complexes on Holter recordings and sustained ventricular tachycardia inducible by one to three extrastimuli. During treatment, programmed stimulation and Holter monitoring were repeated. Efficacy of treatment determined by programmed stimulation (ventricular tachycardia no longer inducible or nonsustained) was compared with three Holter criteria of efficacy: I = 83% or more reduction of ventricular premature complexes and abolition of ventricular tachycardia; II = 50% or more reduction of ventricular premature complexes and 90% or more reduction of couplets and abolition of ventricular tachycardia; III = abolition of ventricular tachycardia in patients with ventricular tachycardia during a baseline Holter recording. Treatments were judged effective by programmed stimulation criteria in only 25% of cases but in 51, 63 and 75% of cases by Holter criterion I, II and III, respectively. Results of programmed stimulation and Holter monitor were discordant (effective by one criterion but ineffective by the other) in 50% of cases using Holter criterion I, in 54% using Holter criterion II and in 61% using Holter criterion III. In the majority of discordant results, treatments appeared efficacious by Holter criteria but ineffective by programmed stimulation criteria, suggesting insensitivity of efficacy by Holter criteria or nonspecificity of induced ventricular tachycardia during treatment, or both.
Keywords:Address for reprints: Soo G  Kim  MD  Division of Cardiology  Montefiore Medical Center  111 East 210th Street  Bronx  New York 10467
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号