300MW机组汽封改造实践及效果 |
| |
引用本文: | 宁志,朱鹏安,吴正平,付冬苗,吴志祥.300MW机组汽封改造实践及效果[J].节能,2012,31(4):49-51. |
| |
作者姓名: | 宁志 朱鹏安 吴正平 付冬苗 吴志祥 |
| |
作者单位: | 1. 安庆电厂,安徽安庆,246000 2. 国电阳宗海发电有限公司,云南昆明,652103 3. 马鞍山二电厂,安徽马鞍山,246000 |
| |
摘 要: | 安徽某电厂一期工程2×300MW机组老化,汽轮机热耗增加,经大机高中压缸部分汽封采用布莱登汽封改造,低压缸两端轴封采用蜂窝汽封改造,煤耗下降3.12g/kWh,节能效果明显。
|
关 键 词: | 布莱登汽封 蜂窝汽封 改造 |
300MW unit seal retrofit practice and the effect |
| |
Affiliation: | NING Zhi,ZHU Peng-An,WU Zheng-ping,et al(Anqing Power Plant,Anqing 246000,China) |
| |
Abstract: | a Anhui power plant first phase project is two 300MW class power units,the unit steam turbine is aging,thermal efficiency at generator terminals is increased,so they need to make the transformation,improve efficiency,through research conducted 1# turbine steam seal reformation of big machine,high pressure cylinder part adopts the Brandon steam seal,and low pressure cylinder adopts the honeycomb steam seal.After the transformation of coal consumption decrease in 3.12g/kWh,obvious energy saving effect. |
| |
Keywords: | the Brandon steam seal the honeycomb steam seal transformation |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
|