摘    要:《高层建筑设计防火规范》要求高层建筑的燃油、燃气的锅炉房应设置水喷雾灭火系统。由于这两种锅炉房火灾分别属于液体火灾和气体火灾 ,水喷雾的设计喷雾强度、喷雾时间、喷头的选用及喷头的布置方法不同。结合北京银谷大厦地下锅炉房的水喷雾设计 ,简要介绍了燃油、燃气锅炉房的水喷雾设计及水雾喷头的选用方法。

关 键 词:燃油、燃气锅炉房  水喷雾灭火系统  喷雾强度  水雾喷头  雨淋阀组

On design of water spray fire control system for oil or gas based boiler house
Zhang Ping.On design of water spray fire control system for oil or gas based boiler house[J].Water & Wastewater Engineering,2004,30(3):62-67.
Authors:Zhang Ping
Abstract:The water spray fire control system is required for oil or gas based boiler house in compliance of the national design norm of fire control system for high rise building. In this case the fire accidents could be classified into liquid or gas caused according to the applied fuels respectively of the boiler. Every design parameters such as spray intensity, spray duration, kind and layout of nozzles have to be arranged properly matching with the type of applied fuel. By a practical project of underground boiler house in Yingu Building in Beijing, the considerations in design of water spray fire control system for both gas and liquid based boiler houses, including the selection of parameters and nozzles are presented briefly.