活性炭吸附/Fenton试剂氧化法处理造纸厂污冷凝水的研究
引用本文:罗刚,黄君礼.活性炭吸附/Fenton试剂氧化法处理造纸厂污冷凝水的研究[J].哈尔滨建筑大学学报,1999,32(6):59-62.
作者姓名:罗刚  黄君礼
作者单位:哈尔滨建筑大学市政环境工程学院!黑龙江哈尔滨150090
摘    要:采用活性炭吸附过滤/Fenton试剂氧化法,对硫酸盐木浆造纸厂污冷凝水中的难降解有机物的去除效果进行了研究。并对Fenton试剂氧化法对COD去除率的各种实验条件及影响因素进行了详细研究。结果表明,当H2O2与Fe^2+的社量比在8:1-10:1之间时,pH3-5,反应时间为1h,H2O2投量为6.6mL/L污冷凝水时,即去除每mg/L COD需要H2O2 0.2mmol,Fe^2+0.02mmo

关 键 词:污冷凝水  化学氧化  活性炭吸附  造纸废水

A study on treatment of distilled water containing pollutants from paper mill by adsorption with granular activated carbon and by oxidation with Fenton reagent
LUO Gang,HUANG Jun-li,SUN Hong.A study on treatment of distilled water containing pollutants from paper mill by adsorption with granular activated carbon and by oxidation with Fenton reagent[J].Journal of Harbin University of Civil Engineering and Architecture,1999,32(6):59-62.
Authors:LUO Gang  HUANG Jun-li  SUN Hong
Abstract:
Keywords:condensed water containing pollutants  Fenton reagent  chemical oxidation  adsorption with activated carbon