一种可靠经济实用的无人值班变电站典型设计
引用本文:张继芬,唐田.一种可靠经济实用的无人值班变电站典型设计[J].电网技术,1998,22(7):38-41.
作者姓名:张继芬  唐田
作者单位:福建省电力设计院,350003,福州
摘    要:文章介绍了一种无人值班变电站典型设计,该设计简化了电气主接线,在保证可靠性的同时对传统的电气二次线作了较大改进,取消了中央信号装置及控制屏,设计合理,结构简单,采取了中央信号装置及控制屏,设计合理,结构简单,采限了较完善的消防措施。

关 键 词:无人值班  变电站  典型设计
修稿时间:1998年1月22日

A TYPICAL DESIGN FOR NON-ATTENDED SUBSTATION
Zhang Jifen,Tang Tian.A TYPICAL DESIGN FOR NON-ATTENDED SUBSTATION[J].Power System Technology,1998,22(7):38-41.
Authors:Zhang Jifen  Tang Tian
Abstract:This Paper decribes a typical design for non attended substation. The main electric connection of substation is simplified. The structure of the substation is simple and rational because the great improvement has been made for the conventional secondary electric system and the central singnaling devices and conventional panels are abolished. Some substations built according to the typical design are operated in telecontrol mode and the correct rate of control is 100% since they put into operation, and their investment can be decreased by 5% to 10%. The land occupied by the whole substation is reduced.
Keywords:Non attended  Substation  Typical design