Coal combustion characteristics in a fluidized bed combustor with a draft tube |
| |
Authors: | Woon-Jae Lee Yong-Jun Cho Jung-Rae Kim Sang Done Kim |
| |
Affiliation: | 1. Department of Chemical Engineering, Korea Advanced Institute of Science and Technology, 305-701, Taejon, Korea
|
| |
Abstract: | The effects of gas velocity to draft tube (3–6 Um), bed temperature (800–900°C) and excess air ratio (0–30%) on the total entrainment rate, overall combustion efficiency and heat transfer coefficient have been determined in an internally circulating fluidized bed combustor with a draft tube. The total entrainment rate increases with an increase in gas velocity to draft tube, but decreases with increasing bed temperature and excess air ratio. The overall combustion efficiency increases with increasing excess air ratio, but decreases with increasing gas velocity to draft tube. The overall combustion efficiency obtained in internally circulating fluidized beds was found to be somewhat higher than that in a bubbling fluidized bed combustor. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|