首页 | 官方网站   微博 | 高级检索  
     


The effects of operating conditions on emissions from masonry heaters and sauna stoves
Authors:Jarkko Tissari  Kati Hytönen  Olli Sippula  Jorma Jokiniemi
Affiliation:1. Fine Particle and Aerosol Technology Laboratory, University of Kuopio, PO Box 1627, 70211 Kuopio, Finland;2. VTT, Technical Research Centre of Finland, Fine Particles, PO Box 1000, 02044 VTT, Espoo, Finland
Abstract:Emissions from masonry heaters and sauna stoves were studied. In the sauna stove the production of organic gaseous carbon (OGC) at 10 gC kg?1 (per kilogram of fuel), carbon monoxide (CO) at 55 g kg?1, fine particle mass (PM1) at 5 g kg?1 and number emissions (N) at 1.8 × 1015 kg?1 was higher than in other measured appliances. In a modern technology masonry heater with a unique grate, the emissions were very low: 0.4 gC kg?1 OGC, 14 g kg?1 CO and 0.7 g kg?1 PM1. Conventional masonry heaters, using small logs, clearly produced higher emissions when compared to using large logs. Doubling the fuel load caused emission factors to increase by up to 4- times (OGC), except for the number emission, which decreased from 4.0 × 1014 to 2.0 × 1014 kg?1. From the conventional masonry heater 90% of the PM was emitted during the firing phase. Its combustion process is different to that in stoves or conventional open fireplaces. The insufficient supply of air, due to too fast pyrolysis, and increased ash release, due to the high combustion temperature, are the main parameters which cause high particle and gas emissions in masonry heaters and sauna stoves.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23